Across-The-Line (ATL) Bypass
- RX2E Combination Soft Starter with MX2 Technology (200HP, 480V Severe Duty – NEMA3R)$9,834.50Extended Part No: RX2E-200-480-3RKP Low voltage soft starter with an across the line bypass, 400A circuit breaker, NEMA12 enclosure
- RX4E Combination Soft Starter with MX4 Technology (250HP, 480V Heavy Duty – 302A max – NEMA 3R) 65k$10,050.30Extended Part No: RX4E-250-480-3RKP-HB Low voltage soft starter with across the line bypass, 400A circuit breaker, NEMA 3R enclosure
- RX3E Combination Soft Starter with MX3 Technology (200HP, 480V Severe Duty – 240A max – NEMA12)$10,050.95Extended Part No: RX3E-200-480-12KP Low voltage soft starter with an across the line bypass, 400A circuit breaker, NEMA12 enclosure
- RX2E Combination Soft Starter with MX2 Technology (250HP, 480V Severe Duty – NEMA12)$10,164.05Extended Part No: RX2E-250-480-12KP Low voltage soft starter with an across the line bypass, 400A circuit breaker, NEMA12 enclosure
- RX4E Combination Soft Starter with MX4 Technology (300HP, 480V Heavy Duty – 361A max – NEMA 3R) 65k$10,256.35Extended Part No: RX4E-300-480-3RKP-HB Low voltage soft starter with across the line bypass, 600A circuit breaker, NEMA 3R enclosure
Run Duty Integral Bypass
- MX4PB Combination Soft Starter with EMX4i Technology (300HP, 240V Standard Duty – 720A max) 65K$16,857.10Extended Part No: MX4PB-SD-300-2-4-HB Combination soft starter with run duty integral bypass, 1200A circuit breaker and NEMA4 enclosure. Max Amp Rating: 350% for 30 seconds, 1.15 Service Factor
- MX4PB Combination Soft Starter with EMX4i Technology (500HP, 460V Heavy Duty – 590A max) 65K$16,857.75Extended Part No: MX4PB-HD-500-4-4-HB Combination soft starter with run duty integral bypass, 1200A circuit breaker and NEMA4 enclosure. Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
- MX4PB Combination Soft Starter with EMX4i Technology (600HP, 460V Standard Duty – 720A max) 65K$16,857.75Extended Part No: MX4PB-SD-600-4-4-HB Combination soft starter with run duty integral bypass, 1200A circuit breaker and NEMA4 enclosure. Max Amp Rating: 350% for 30 seconds, 1.15 Service Factor
- MX4PB Combination Soft Starter with EMX4i Technology (250HP, 240V Heavy Duty – 590A max) 65K$16,857.75Extended Part No: MX4PB-HD-250-2-4-HB Combination soft starter with run duty integral bypass, 1000A circuit breaker and NEMA4 enclosure. Max Amp Rating: 450% for 30 seconds, 1.25 Service Factor
- MX4PB Combination Soft Starter with EMX4i Technology (350HP, 240V Standard Duty – 904A max) 65K$17,185.35Extended Part No: MX4PB-SD-350-2-4-HB Combination soft starter with run duty integral bypass, 1200A circuit breaker and NEMA4 enclosure. Max Amp Rating: 350% for 30 seconds, 1.15 Service Factor
Pump Panels
Need help finding the packaged soft starter(s) you need?